Your Source For
Polyurethane · Parts · Equipment · Coatings
polysource logo main
  • Mon – Fri 8am – 4:30pm Pacific
gusmer gh 2 spray foam proportioner

Gusmer GH-2 Proportioner

The Gusmer GH-2 Proportioner delivers robust hydraulic performance for spray foam applications with up to 28 lb/min flow and 10 kW heater power.

Add to Quote

Description

The Gusmer GH-2 Proportioner is engineered for reliability and simplicity in demanding spray-foam installations. Built on the proven Graco Reactor 2 hydraulic chassis, the unit features a 10 kW heater, either 230 V 1-phase or 400 V 3-phase power options, and a high-pressure pump system designed to handle polyurethane materials with a 1:1 mix ratio. Ideal for residential and commercial insulation jobs, such as wall cavity fill, rim joists, roof decks and even concrete lifting, the GH-2 offers a maximum fluid temperature of 190 °F (88 °C) and a max flow rate of 28 lb/min. Service access is simplified via standard off-the-shelf components in the electrical cabinet. With compact dimensions (54″ H × 32″ W × 21″ D) and approx. 585 lb weight, the GH-2 is rugged yet mobile enough for job-site deployment. Whether outfitted with heated hose and whip or integrated into a larger spray system, the Gusmer GH-2 Proportioner ensures consistent, high-performance results.
gusmer gh 2 spray foam proportioner
Category: Brand:

Spray Foam Machine Info & Resources

Technical Specifications

  • Full-load amperage: 79 A at 230 V 1-phase (model 26C200)
  • Maximum working fluid pressure: 2,000 psi (138 bar)
  • Maximum heated hose length (including whip): 310 ft (94.5 m)
  • Model 26C200: GH-2 Base, 10 kW, 230 V, 1-phase.
  • Model 26C201: GH-2 Base, 10 kW, 230 V, 3-phase.
  • Model 26C202: GH-2 Base, 10 kW, 400 V, 3-phase.
  • Package variations (guns, hoses)

Frequently Asked Questions

Service & Support

What is the recommended heater warm-up time before spraying to ensure the GH-2 reaches optimal fluid temperature?

The GH-2 offers a maximum fluid temperature of 190 °F (88 °C). The equipment manual indicates you should pre-heat and circulate prior to pressure spraying.

Is it possible to extend the heated hose length on the GH-2 beyond the standard package without losing performance?

The GH-2 spec sheet lists a maximum heated hose length of 94.5 m (310 ft) including the whip hose. Extending beyond this length could risk insufficient material delivery pressure, heat loss, or mixing issues.

What maintenance schedule should be followed on the GH-2 for the hydraulic drive, packings and filters to avoid downtime?

According to the general GH-2/GH-4 manual, check the hydraulic fluid level, wipe pump shaft of any seepage and inspect general condition weekly. And annually if heavily used, disassemble proportioning pumps, inspect pistons/cylinders, replace packings if necessary.